ZJ-DR125
One component pre curing thermal conductive silicon gel

ZJ-DR125 is a single component thermal conductive silicon gel, which is suitable for bonding and heat dissipation of various automotive electronic equipment, communication equipment, network terminal equipment, electronic and electrical equipment and modules.

Product features

1. One component silicon gel, without mixing and curing;

2. High thermal conductivity and low thermal resistance;

3. High surface stickiness, reworkable;

4. Soft, stress free, easy to compress;

5. Medium thickness, approximately 0.1-1mm;

6. No settlement, no flow, and can fill any uneven gap.

Product parameters
Main parameters of ZJ-DR125
Project

ZJ-DR125

Testing standards

Extrusion rate,mL/min

25

30mL EFD syringe for gluing, pressure 621kPa

Density,g/cm3

2.8

GB/T 533

Offset under different forces

@ 0.0060MPa

@ 0.0100MPa

@ 0.0175MPa

@ 0.0300MPa

@ 0.0480MPa

Shifting,%

30

40

50

60

70

ASTM C165

Minimum adhesive layer thickness,mm

0.10

/

Thermal conductivity,W/m·K

2.5

ISO 22007-2

Total mass loss Outgassing Outgassing (TML),%

0.12

ASTM E595

Specific heat capacity,J/g·K

1

ASTM E1269

Working temperature,℃

-55~200

/

Volume resistivity,Ω·cm

1×1014

GB/T 1692

Flame retardant grade

V0

UL 94

RoHS standard Conform to

/

Storage period, months

18

/

The data in the table is for reference only, please refer to the measured data
Operation and Safety
  • ZJ-DR125 is a fully cured material that does not require any curing process and can be applied through automated equipment with air supply.
  • Safety instructions:
  • Zhijiang ZJ-DR125 is a single component thermal conductive silicon gel, which contains neither toxic substances nor corrosive substances. Special handling precautions may be required, and general industrial hygiene regulations should be followed.
  • Hazard indications/safety recommendations/transportation rules:
  • Wear protective gloves for long-term or repeated contact.
  • Keep away from heat sources/sparks/open flames, prohibit smoking, and keep the container closed. Use explosion-proof electrical/ventilation/lighting equipment.
  • Transport according to non hazardous materials.
Color and packaging

300mL/piece or packaged according to customer requirements

Storage and expiration date

Sealed storage at room temperature, cool and ventilated conditions.